差異處
這裏顯示兩個版本的差異處。
下次修改 | 前次修改 | ||
tech:pve7_megaraid [2022/07/08 16:19] – 建立 jonathan | tech:pve7_megaraid [2022/07/08 16:36] (目前版本) – jonathan | ||
---|---|---|---|
行 24: | 行 24: | ||
megacli -AdpAllInfo -aAll | megacli -AdpAllInfo -aAll | ||
</ | </ | ||
+ | * ++顯示結果|< | ||
+ | root@pve-48: | ||
+ | |||
+ | Adapter #0 | ||
+ | |||
+ | ============================================================================== | ||
+ | Versions | ||
+ | ================ | ||
+ | Product Name : AVAGO 3108 MegaRAID | ||
+ | Serial No : | ||
+ | FW Package Build: 24.15.0-0018 | ||
+ | |||
+ | Mfg. Data | ||
+ | ================ | ||
+ | Mfg. Date : 00/00/00 | ||
+ | Rework Date : 00/00/00 | ||
+ | Revision No : | ||
+ | Battery FRU : N/A | ||
+ | |||
+ | Image Versions in Flash: | ||
+ | ================ | ||
+ | BIOS Version | ||
+ | Ctrl-R Version | ||
+ | Preboot CLI Version: 01.07-05:# | ||
+ | FW Version | ||
+ | NVDATA Version | ||
+ | Boot Block Version : 3.07.00.00-0003 | ||
+ | |||
+ | Pending Images in Flash | ||
+ | ================ | ||
+ | None | ||
+ | : | ||
+ | : | ||
+ | Allow HDD/SSD Mix in VD : No | ||
+ | Allow SATA in Cluster | ||
+ | Max Chained Enclosures | ||
+ | Disable Ctrl-R | ||
+ | Enable Web BIOS : No | ||
+ | Direct PD Mapping | ||
+ | BIOS Enumerate VDs : Yes | ||
+ | Restore Hot Spare on Insertion | ||
+ | Expose Enclosure Devices | ||
+ | Maintain PD Fail History | ||
+ | Disable Puncturing | ||
+ | Zero Based Enclosure Enumeration : No | ||
+ | PreBoot CLI Enabled | ||
+ | LED Show Drive Activity | ||
+ | Cluster Disable | ||
+ | SAS Disable | ||
+ | Auto Detect BackPlane Enable | ||
+ | Use FDE Only : No | ||
+ | Enable Led Header | ||
+ | Delay during POST : 0 | ||
+ | EnableCrashDump | ||
+ | Disable Online Controller Reset : No | ||
+ | EnableLDBBM | ||
+ | Un-Certified Hard Disk Drives | ||
+ | Treat Single span R1E as R10 : No | ||
+ | Max LD per array : 16 | ||
+ | Power Saving option | ||
+ | Max power savings option is not allowed for LDs. Only T10 power conditions are to be used. | ||
+ | Default spin down time in minutes: 30 | ||
+ | Enable JBOD : No | ||
+ | TTY Log In Flash : No | ||
+ | Auto Enhanced Import | ||
+ | BreakMirror RAID Support | ||
+ | Disable Join Mirror | ||
+ | Enable Shield State : Yes | ||
+ | Time taken to detect CME : 60s | ||
+ | |||
+ | Exit Code: 0x00 | ||
+ | </ | ||
* 顯示 RAID 狀態 <cli> | * 顯示 RAID 狀態 <cli> | ||
megaclisas-status | megaclisas-status | ||
- | </ | + | </ |
+ | * ++顯示結果|< | ||
root@pve-48: | root@pve-48: | ||
-- Controller information -- | -- Controller information -- | ||
行 45: | 行 118: | ||
c0u0p4 | c0u0p4 | ||
c0u1p0 | c0u1p0 | ||
+ | </ | ||
+ | * 查詢 RAID 內單一硬碟的 smart 資訊 Exp. RAID 在 /dev/sdb 要看裡面的第一顆資訊< | ||
+ | smartctl -a -d megaraid,0 /dev/sdb | ||
+ | </ | ||
+ | * ++ 顯示結果|< | ||
+ | root@pve-48: | ||
+ | smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.35-3-pve] (local build) | ||
+ | Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org | ||
+ | |||
+ | === START OF INFORMATION SECTION === | ||
+ | Model Family: | ||
+ | Device Model: | ||
+ | Serial Number: | ||
+ | LU WWN Device Id: 5 001b44 4a702e696 | ||
+ | Firmware Version: 415020WD | ||
+ | User Capacity: | ||
+ | Sector Size: 512 bytes logical/ | ||
+ | Rotation Rate: Solid State Device | ||
+ | Form Factor: | ||
+ | : | ||
+ | : | ||
+ | 232 Available_Reservd_Space 0x0033 | ||
+ | 233 NAND_GB_Written_TLC | ||
+ | 234 NAND_GB_Written_SLC | ||
+ | 241 Host_Writes_GiB | ||
+ | 242 Host_Reads_GiB | ||
+ | 244 Temp_Throttle_Status | ||
+ | |||
+ | SMART Error Log Version: 1 | ||
+ | No Errors Logged | ||
+ | |||
+ | SMART Self-test log structure revision number 1 | ||
+ | No self-tests have been logged. | ||
+ | |||
+ | Selective Self-tests/ | ||
</ | </ | ||
行 50: | 行 158: | ||
* https:// | * https:// | ||
* http:// | * http:// | ||
+ | * https:// | ||
+ | * https:// | ||
{{tag> | {{tag> | ||