差異處

這裏顯示兩個版本的差異處。

連向這個比對檢視

兩邊的前次修訂版 前次修改
下次修改
前次修改
tech:pve7_megaraid [2022/07/08 16:22] jonathantech:pve7_megaraid [2022/07/08 16:36] (目前版本) jonathan
行 95: 行 95:
  
 Exit Code: 0x00 Exit Code: 0x00
-</cli>+</cli>++
   * 顯示 RAID 狀態 <cli>   * 顯示 RAID 狀態 <cli>
 megaclisas-status megaclisas-status
行 118: 行 118:
 c0u0p4  | SSD  | 2114FV459101 WDC WDS100T2B0A-00SM50 415020WD | 931.0 GB | Online, Spun Up | 6.0Gb/ | N/A  | [252:4]  | 5        c0u0p4  | SSD  | 2114FV459101 WDC WDS100T2B0A-00SM50 415020WD | 931.0 GB | Online, Spun Up | 6.0Gb/ | N/A  | [252:4]  | 5       
 c0u1p0  | SSD  | 21116Q441114 WDC WDS100T2B0A-00SM50 401020WD | 931.0 GB | Online, Spun Up | 6.0Gb/ | N/A  | [252:5]  | 4        c0u1p0  | SSD  | 21116Q441114 WDC WDS100T2B0A-00SM50 401020WD | 931.0 GB | Online, Spun Up | 6.0Gb/ | N/A  | [252:5]  | 4       
 +</cli>++
 +  * 查詢 RAID 內單一硬碟的 smart 資訊 Exp. RAID 在 /dev/sdb 要看裡面的第一顆資訊<cli>
 +smartctl -a -d megaraid,0 /dev/sdb
 +</cli>
 +    * ++ 顯示結果|<cli>
 +root@pve-48:~# smartctl -a -d megaraid,0 /dev/sdb
 +smartctl 7.2 2020-12-30 r5155 [x86_64-linux-5.15.35-3-pve] (local build)
 +Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
 +
 +=== START OF INFORMATION SECTION ===
 +Model Family:     WD Blue / Red / Green SSDs
 +Device Model:     WDC  WDS100T2B0A-00SM50
 +Serial Number:    2114FV455312
 +LU WWN Device Id: 5 001b44 4a702e696
 +Firmware Version: 415020WD
 +User Capacity:    1,000,204,886,016 bytes [1.00 TB]
 +Sector Size:      512 bytes logical/physical
 +Rotation Rate:    Solid State Device
 +Form Factor:      2.5 inches
 +:
 +:
 +232 Available_Reservd_Space 0x0033   100   100   004    Pre-fail  Always             100
 +233 NAND_GB_Written_TLC     0x0032   100   100   ---    Old_age   Always             411623
 +234 NAND_GB_Written_SLC     0x0032   100   100   ---    Old_age   Always             435405
 +241 Host_Writes_GiB         0x0030   253   253   ---    Old_age   Offline      -       93813
 +242 Host_Reads_GiB          0x0030   253   253   ---    Old_age   Offline      -       152365
 +244 Temp_Throttle_Status    0x0032   000   100   ---    Old_age   Always             0
 +
 +SMART Error Log Version: 1
 +No Errors Logged
 +
 +SMART Self-test log structure revision number 1
 +No self-tests have been logged.  [To run self-tests, use: smartctl -t]
 +
 +Selective Self-tests/Logging not supported
 </cli>++ </cli>++
  
行 123: 行 158:
   * https://www.sven-mette.com/install-lsi-megaraid-storage-manger-on-proxmox-6-2/   * https://www.sven-mette.com/install-lsi-megaraid-storage-manger-on-proxmox-6-2/
   * http://www.ttlsa.com/tools/megacli-monitor-raid-status/   * http://www.ttlsa.com/tools/megacli-monitor-raid-status/
 +  * https://www.mybluelinux.com/debian-linux-and-lsi-megaraid-sas/
 +  * https://unix.stackexchange.com/questions/485463/smartctl-megaraid-n-how-to-find-the-right-value-for-n
  
 {{tag>pve megaraid}} {{tag>pve megaraid}}
  
  • tech/pve7_megaraid.1657268572.txt.gz
  • 上一次變更: 2022/07/08 16:22
  • jonathan